ThinkPad Fan Control

Fan, temperature and CPU power-limit control for a ThinkPad T495 (Ryzen 5 PRO 3500U "Picasso", one physical fan that thinkpad_acpi exposes as fan1 and fan2 with identical values) on Linux Mint 22.3. This is version 2.0.0. Every schema, path and behaviour is specified in docs/CONTRACT.md; this README explains it in prose. When the two disagree, the contract wins.

Use at your own risk. This is written for one machine, a ThinkPad T495 with a Ryzen 5 PRO 3500U. It takes over the embedded controller's fan control and changes the CPU's power limits through ryzenadj. On other hardware it may not work, or it may keep the fan slower or the CPU hotter than the laptop's own firmware would. Not affiliated with Lenovo; "ThinkPad" is Lenovo's trademark.

There are two parts:

  • thinkpad-fan-controld is a root daemon under systemd. It reads the die temperature, filters it, walks a fan curve, writes /proc/acpi/ibm/fan, keeps the EC watchdog armed, plays the critical alert and publishes what it is doing.
  • Fan Control is the dashboard. app.py is a GTK window with a tray icon and an embedded WebKit view. server.py serves the same page to a normal browser. Both are built on fanlib.py, which reads the sensors, talks to the daemon, runs the power-limit (TDP) features and serves the HTTP API.

Either part works without the other. The daemon needs no GUI. Without the daemon, the GUI can still read sensors and set the fan by hand, and it shows a red "no thermal protection" warning while it does.

The dashboard's Overview tab, with simulated data from tests/mock_api.py

Contents: 1 Pieces · 2 Install · 3 Dashboard · 4 Controller · 5 Holds · 6 Power · 7 Simulator · 8 Keys · 9 Files · 10 Troubleshooting · 11 Tests · 12 License


1. The pieces and how they talk

                 /etc/thinkpad-fan-control/config.json   (curve, response, alerts)
                     ▲ written only by the daemon (--save-config)   │ hot-reloaded (mtime)
                     │                                              ▼
 ┌────────────────────┐  sudo fan-config-save.sh      ┌──────────────────────────┐
 │ Fan Control GUI    │ ────────────────────────────▶ │ thinkpad-fan-controld    │
 │ app.py / server.py │  control.sock (JSON lines):   │ root, systemd Type=notify│
 │ + fanlib.py        │ ◀───── hold · resume ──────▶  │                          │
 │ index.html served  │        status · test_alert    │ k10temp + amdgpu ─▶ curve│
 │ on 127.0.0.1:7070  │ ◀── state.json (every tick)── │ ─▶ /proc/acpi/ibm/fan    │
 │                    │ ◀── history.json (10 s) ───── │    + EC watchdog         │
 │                    │ ◀── /var/log/…log (tail) ──── │                          │
 └────────────────────┘                               └──────────────────────────┘
      │ sudo ryzenadj-set-tdp.sh / sudo ryzenadj --info   (SMU power limits)
      │ sudo fan-set-level.sh                             (only while the daemon is down)
      ▼ sudo systemctl start|stop|restart thinkpad-fan-control.service
Channel Direction What it carries
/run/thinkpad-fan-control/state.json daemon → GUI A snapshot written every sample (1 s by default) and right after any change: raw, fast and slow temperatures, the commanded level, the level and RPM the EC reports, why the fan is where it is (reason), the curve step, hold and critical state, learned RPM per level, whether fan control is available. The daemon counts as active when this file parses and its ts is less than 3 × sample_interval + 2 seconds old.
/run/thinkpad-fan-control/history.json daemon → GUI The last 30 minutes of samples (at most 1800) and the last 200 events (level changes, critical, holds, config reloads, power-source switches, sensor loss, alerts). It seeds the chart. Written every 10 s and after each event.
/run/thinkpad-fan-control/control.sock GUI ↔ daemon A Unix socket, root:<your gid>, mode 0660. The daemon also checks the caller's uid (root or you). One JSON object goes in and one JSON line comes back: hold, resume, status, test_alert. A hold is applied before the reply is sent.
config.json GUI → daemon The GUI posts a partial config. sudo fan-config-save.sh passes it to thinkpad-fan-controld --save-config, which validates it, writes it atomically and reports which keys it rejected. The running daemon notices the new mtime on its next tick.
/var/log/thinkpad-fan-control.log daemon → GUI Plain text, one line per event. The Log view tails it.
sudo wrappers GUI → root fan-set-level.sh (only while the daemon is down), fan-config-save.sh, ryzenadj-set-tdp.sh, ryzenadj --info, and systemctl start/stop/restart of the unit. The sudoers file allows nothing else.

systemd creates everything under /run/thinkpad-fan-control/ (RuntimeDirectory=) and deletes it when the daemon stops, so a leftover file never looks like a running daemon. A hold is kept only in the daemon's memory, so a daemon restart or a reboot drops it.

The dashboard's HTTP API (fanlib.py, §14 of the contract) is small:

GET Returns
/, /index.html the dashboard
/api/status everything the dashboard shows: temperatures, fan, mode, daemon state, SMU/TDP readouts, battery
/api/config the sanitized config.json
/api/history?minutes=N up to 30 min of samples and events, with TDP/power merged in from the backend's own sampler
/api/log?lines=N the last N log lines (default 200, max 2000), NUL-stripped
/api/settings the per-user settings
POST Does
/api/fan/hold {"level","seconds"} hold through the daemon; when the daemon is down, the fallback described in §5
/api/fan/resume end any hold
/api/fan/set {"level"} old name for hold, using the default hold duration
/api/daemon/start|stop|restart sudo -n systemctl … (Advanced section of the dashboard)
/api/tdp/set, /api/tdp/lock, /api/tdp/vrm_unlock, /api/tdp/restore_stock power limits (§6)
/api/config save a partial config through the daemon; the reply includes rejected
/api/settings save ui.*, apply_tdp_at_startup, autostart_enabled
/api/alert/test play the alert (limited to one every 10 s by the daemon)

2. Install, upgrade, uninstall

sudo ./install.sh                 # first install, and every upgrade
sudo ./install.sh --user NAME     # if $SUDO_USER is not the desktop user
sudo ./uninstall.sh               # keeps config and logs
sudo ./uninstall.sh --purge       # removes those too

What install.sh does

The installer is safe to run repeatedly. Running it over v1, over v2, or twice in a row all work, and it restarts the daemon only when something the daemon loads has changed. The steps run in this order:

  1. Preflight. Nothing on the system changes until this step passes. The installer copies the files it will install to a private staging directory, so the files it checks are the files it installs. It then: byte-compiles the daemon, fanlib.py, app.py and server.py; checks that the daemon declares a 2.x VERSION; runs bash -n on the root wrappers; runs systemd-analyze verify on the unit; renders the sudoers file for your user and checks it with visudo -c, and checks that every rule names only the contract's commands (visudo alone would accept NOPASSWD: ALL); checks that alert.wav is a WAV file; and reads /proc/acpi/ibm/fan to see whether fan control is available now (read only).
  2. Backups. Every file the run replaces is first copied to /var/backups/thinkpad-fan-control/<stamp>/<original path>. If no file in /etc/modprobe.d/ and nothing on the kernel command line sets thinkpad_acpi fan_control=1, the installer adds it to /etc/modprobe.d/thinkpad_acpi.conf under a marker comment.
  3. Binaries. thinkpad-fan-controld, fan-set-level.sh, fan-config-save.sh and ryzenadj-set-tdp.sh go into /usr/local/bin under the same names as before, so an old GUI that is still running keeps working. The fallback alert sound goes to /usr/local/share/thinkpad-fan-control/alert.wav.
  4. daemon.env. Your uid, gid, home and runtime directory, plus the TDP ceilings. Values already in the file are kept. Invalid values and unknown keys are reported and replaced (the old file stays in the backup).
  5. Config migration. The new daemon rewrites config.json through --save-config, since it is the only program allowed to write that file. A v1 config comes out as schema 2: poll_interval is dropped, a disabled watchdog becomes 60 s, curves equal to the v1 defaults become the v2 defaults, and new keys are added. Every other value is kept as it was, including v1's hysteresis of 5 (the v2 default is 6); change it in the dashboard's Response card if you want the new default. The resulting curve and any rejected keys are printed. On a first install the default config is written.
  6. Log. A log larger than 2 MiB is rotated once: it becomes .1 with NUL bytes from old crashes removed and is then gzipped (an existing .1.gz moves to .2.gz). The logrotate snippet is installed. The daemon opens the log for each line, so it needs no signal.
  7. sudoers. The rendered file is checked with visudo again and moved into place in one step.
  8. Unit. The unit is installed, then daemon-reload and enable run. The daemon is restarted only if its binary, the unit or daemon.env changed, or if the running daemon reports a different version or no fresh state.json. Otherwise it keeps running. A restart drops any active manual hold; the installer says so, and names the hold when there is one.
  9. Post-check. Within 10 s the unit must be active and state.json must have a timestamp newer than the restart. If not, the installer prints the last 20 journal lines and the log tail, restores every file this run replaced (and removes files it created), returns the service to its previous state (restarting the previous daemon if it had been running), and exits 1. The same rollback runs if any earlier step fails or the run is interrupted. Only the one-time log rotation is not undone, and it loses no lines.
  10. Desktop entries. ~/Desktop/Fan Control.desktop (only if ~/Desktop exists) and ~/.config/autostart/fan-control.desktop, which starts the app in the tray. Both are written as you, not as root, and only when their content changes. If the autostart entry exists, its X-GNOME-Autostart-enabled and Hidden values are kept, so turning autostart off survives upgrades. Only a first install writes true. If you deleted the entry, an upgrade recreates it switched off, so the dashboard's autostart switch still has a file to change.
  11. Running GUI. If a Fan Control app.py or server.py from this checkout is running, the installer prints Quit and relaunch Fan Control to pick up the new client.

REBOOT REQUIRED. If thinkpad_acpi is loaded but /proc/acpi/ibm/fan has no commands: level … line, the module was loaded without fan_control=1 and nothing can write the fan until it is reloaded with that option. The installer then installs and enables everything, does not start the daemon (its self-test could not pass), and ends with REBOOT REQUIRED. The modprobe option takes effect at the next boot. status: disabled in that file does not mean this; see Troubleshooting.

The installer never writes to /proc/acpi/ibm/fan. Only the daemon does, after its own self-test. The installer also warns if your account has a NOPASSWD: ALL sudo rule from outside this project, because with such a rule the narrow fan-control rules protect nothing.

What uninstall.sh does

  1. It removes the sudoers rule first, so a GUI running without the daemon cannot put the fan back to a fixed level through sudo fan-set-level.sh.
  2. It disables and stops the unit. The daemon's shutdown gives the fan back to the firmware.
  3. It runs fan-set-level.sh auto 0 through the installed wrapper before removing it. This puts the fan back on auto even if something had fixed it while the daemon was down, and turns off the EC watchdog. If /proc/acpi/ibm/fan has no commands: line there is nothing to undo, and this step is skipped.
  4. It removes the binaries, the alert sound, the unit, the logrotate snippet and both desktop entries (desktop entries are removed as you).

/etc/thinkpad-fan-control (config and daemon.env) and the log are kept unless you pass --purge. --purge also removes the learned RPM table, your ~/.config/thinkpad-fan-control settings and /etc/modprobe.d/thinkpad_acpi.conf. That last file is removed only if install.sh created it (marker comment) and it contains nothing else. Backups are always kept. The uninstaller asks for confirmation; --yes skips the question. You can re-run it safely: a finished uninstall leaves the fan alone on a second run. install.sh and uninstall.sh share a lock, so they never run at the same time.


3. Running the dashboard

./launch.sh                  # window (runs python3 app.py from the checkout)
./launch.sh --tray           # start hidden in the tray (the autostart entry passes --tray too)
./launch.sh --port 7071      # another port for the local API
python3 server.py            # browser mode: http://127.0.0.1:7070 (--no-browser, --port N)

Closing the window leaves the app running in the tray; quit it from the tray menu. The GTK app allows only one instance, so launching it again brings the existing window to the front. If no AppIndicator library is installed, --tray is ignored, the window opens, and closing it quits the app.

The tray shows the control temperature as its label ( 78°). Its menu has a status line (78 °C · 4000 RPM · Curve, or Hold 3 · 12:34 left), Open dashboard, Hold fan at… (levels 0–7, Firmware auto and Maximum, each for the default hold duration shown in the label), Resume auto curve, Restore stock power limits (shown only while VRM current is unlocked) and Quit. You get a desktop notification when the daemon enters critical and another when a hold ends by itself.

Quitting cleanly (tray Quit, Ctrl+C, SIGTERM) undoes what this session did: a hold this app started is resumed, a fan level set without the daemon goes back to auto, and a VRM unlock is reverted to stock.

The HTTP API listens on 127.0.0.1:7070 only. It rejects requests whose Host, Origin or Sec-Fetch-Site do not match its own address, which stops web pages (CSRF, DNS rebinding) from using it. It has no login, though: any program on this machine that can open a TCP connection to 127.0.0.1:7070 can use it, with your sudo rules behind it (fan holds, TDP, daemon start/stop). On a single-user laptop that is the same trust boundary as your own account. Do not run the GUI on a machine shared with users you do not trust, and turn autostart off if you want the API running only while the dashboard is open.


4. How the controller decides

Inputs

  • Control temperature = max(k10temp Tctl, amdgpu edge), read as floats. Both sensors are on the same die, but CPU alone misses GPU-bound loads. A reading outside 0–150 °C is invalid. Sensors are found by their hwmon name, never by hwmonN number, because the numbers change between boots.
  • Power source from /sys/class/power_supply/AC/online (a missing file counts as AC). The curve switches only after 3 identical readings in a row.
  • The EC via /proc/acpi/ibm/fan: the level it reports, the fan speed (speed:), the status: word, and whether a commands: level … line is present, meaning fan control is available.

Why there are two filters

On this APU, Tctl can jump by up to 11 °C within one second, in bursts that last only a few seconds. A controller that reacts to the raw value flaps between level 7 and disengaged, which is what v1 did: 4000 ↔ 6400 RPM about once a minute under a one-core load. v2 keeps two exponential moving averages (EMAs) of the same signal:

Filter Time constant Used for
T_fast smoothing_up_s = 8 s stepping up, so the fan reacts to real heating within seconds
T_slow smoothing_down_s = 30 s stepping down, so a short dip never releases a step

Both filters start from the first valid reading. A config reload never resets them.

The curves and the measured RPM

A curve has 1–8 steps {temp, level, down?}. Step 0 always starts at 0 °C. These are the defaults. RPM is what this unit's EC reports at that level; only two values have been measured by hand:

AC curve (curve)

Step Up when T_fast ≥ Level Down when T_slow < RPM on this T495
0 — auto (firmware curve) — firmware decides
1 50 °C 4 44 °C (50 − hysteresis 6) learned
2 60 °C 6 54 °C learned
3 70 °C 7 64 °C ≈ 4000 (measured)
4 80 °C disengaged (maximum) 72 °C (explicit down) ≈ 6400 (measured)

Battery curve (battery_curve, used while on battery if use_battery_curve is true)

Step Up when T_fast ≥ Level Down when T_slow <
0 — auto —
1 60 °C 3 54 °C
2 70 °C 5 64 °C
3 80 °C 7 74 °C
4 87 °C disengaged 78 °C (explicit)

A step's release temperature is its explicit down if it has one, otherwise temp − hysteresis (default 6), computed when needed. The top step gets a wider explicit release because of the 4000 → 6400 RPM gap between level 7 and disengaged. Under a steady load the die can sit above 80 °C at level 7 and fall below 75 °C at disengaged, so a 6 °C band there cannot settle. That gap is the whole "top band" problem.

disengaged takes the fan out of EC regulation: it runs as fast as it can (about 6400 RPM here, far above level 7's 4000). full-speed is another name for the same thing and ranks the same. Level 0 stops the fan.

RPM per level is learned, not hard-coded. After 20 s at a commanded level, the daemon adds the EC speed to a list of the last 50 readings for that level. The median is published as state.rpm_by_level, shown in the curve editor and hold grid, and saved in /var/lib/thinkpad-fan-control/rpm.json when it changes by 50 RPM or more. Levels the fan has never sat at show a ~ estimate until they are measured.

Each tick (every sample_interval, default 1 s)

  1. Sensor loss. After three invalid readings in a row, the fan goes to auto (or stays disengaged if critical is active), one log line is written, and reason becomes sensor_lost. When readings come back, both filters restart from the new reading and the curve is re-seated.
  2. Filters update.
  3. Power source. When the 3-reading check confirms a switch, the log says Power -> battery|AC and the curve is re-seated.
  4. Config reload if config.json's mtime changed. An unreadable or invalid file keeps the running config and is logged once. Filters and holds are never reset by a reload.
  5. Critical. Entered when the raw temperature is at or above critical_temp (90) on two samples in a row, or at or above 93 once. The fan goes to disengaged regardless of the curve or a hold. The alert sound plays (again every alert_cooldown = 300 s while critical lasts, as ALERT: critical since HH:MM:SS (raw …, slow …)), and the GUI shows a desktop notification. Critical clears only when T_slow < 90 − 8 = 82 and at least critical_exit_hold_s = 60 s have passed. The fan then goes to the top curve step with fresh dwell timers, and the normal down rules bring it down one step at a time. (Jumping straight to the step matching T_fast dropped to level 7, reheated and re-entered critical in simulation.)
  6. Curve. This is always computed, even while a hold or critical is in control, so curve_level always shows what the curve would do. UP: while T_fast ≥ the next step's temperature, move up one step per tick. DOWN: move down one step when T_slow is below the current step's release temperature and at least dwell_down_s = 45 s have passed since the last UP and at least step_down_spacing_s = 10 s have passed since the last change. So after a heat burst pushes the fan up, it stays at that level for at least 45 s, and a long cool-down steps down every 10 s instead of dropping straight to auto.
  7. Target. The first match wins: critical → disengaged; an active, unsuspended hold → its level; otherwise the curve level.
  8. Hold expiry. The hold is cleared, the log says Override <level> ended (expired), and the curve is re-seated.
  9. Fan write. The daemon writes only when the level changes or the refresh interval has passed (min(20, watchdog / 3) s, so 20 s by default). Each change is one log line: Fan 7 -> disengaged (raw 81.2 fast 80.1 slow 77.9 | step 4/5 ac | up>=80 down<72) [curve]. If the EC reports a level the daemon did not command (other than the watchdog's auto), the daemon logs external fan write detected (level X) once and writes its own level again.
  10. EC watchdog. watchdog 60 by default. If nothing writes the fan for that long (crash, SIGKILL, a hung machine), the embedded controller returns the fan to firmware control on its own. A non-zero value is never below 3 × sample_interval + 15, and the refresh in step 9 keeps it from firing while the daemon is healthy. 0 turns this safety net off; the dashboard offers Off / 60 / 90 / 120.
  11. State. state.json is written every tick; history.json every 10 s and after events.

Re-seating (at start, after a config reload, an AC switch, sensor recovery, a hold ending, or Resume) jumps to the highest step whose temperature is at or below T_fast and restarts the dwell timer. Critical exit is the exception described in step 5.

Start, stop, supervision

The daemon waits up to 60 s (in 2 s steps) for /proc/acpi/ibm/fan and a readable sensor, then runs a self-test: it reads the current level and writes it back. If that write fails (for example thinkpad_acpi without fan_control=1, or a sandbox change that made the file read-only), it logs a FATAL: line and exits 1 instead of claiming to control a fan it cannot touch. Only then does it tell systemd it is ready (Type=notify). It pings systemd's watchdog (WatchdogSec=45) from its main loop, so a hung daemon is killed and restarted. On SIGTERM it logs Daemon stopping — returning fan to firmware control, writes watchdog 0 then level auto, and exits 0. Restart=on-failure with a limit of 5 starts in 300 s means a daemon that keeps crashing stops being restarted instead of filling the log.

Configuration reference (config.json, schema 2)

Key Default Allowed Meaning
sample_interval 1 1–5 s tick period
smoothing_up_s 8 2–30 s time constant of T_fast
smoothing_down_s 30 5–120 s time constant of T_slow
dwell_down_s 45 0–300 s minimum time after an UP before any DOWN
step_down_spacing_s 10 0–60 s minimum time between two DOWN steps
hysteresis 6 0–20 °C release gap for steps without down
critical_temp 90 70–105 °C critical threshold (raw temperature)
critical_exit_margin 8 3–20 °C leave critical when T_slow < critical_temp − margin
critical_exit_hold_s 60 10–600 s minimum time in critical
watchdog 60 0, or 15–120 s EC watchdog; a non-zero value is raised to at least 3·sample_interval + 15
override_max_seconds 7200 60–14400 s longest hold; "Until I resume" uses this
override_ceiling_temp critical_temp − 8 (82) 60 … critical_temp − 1 hold ceiling (§5)
curve, battery_curve see above 1–8 steps {"temp", "level", "down"?}
use_battery_curve true bool
alerts_enabled true bool
alert_sound /home/jhnlstrlclcn/Music/SYSTEM SOUND/90c.mp3 absolute path, at most 400 characters if unreadable when needed, the installed alert.wav plays
alert_cooldown 300 30–3600 s time between repeat alerts

Curve rules the daemon enforces (an invalid curve is rejected as a whole and the previous one kept): temperatures strictly increasing within 0–105 (step 0 is forced to 0); auto only at step 0; the fan level never decreases as temperature rises; no level 0 at 60 °C or above; down between temp − 20 and temp − 1.

Every value the GUI sends is checked by the root daemon (--save-config), not by the GUI. A value that is out of range or the wrong type is not clamped; the key keeps its previous value and is listed under rejected in the reply, which the curve editor shows next to the field. Unknown keys are dropped and reported the same way. The only adjustment the daemon makes deliberately is raising a non-zero watchdog to the minimum above. The dashboard's Response card has smoothing presets Off / Light / Normal / Heavy, which set (smoothing_up_s, smoothing_down_s) to (2, 5) / (4, 15) / (8, 30) / (12, 60).


5. Holds and the safety envelope

A hold keeps the fan at one level for a set time: 0–7, Firmware (auto) or Max (disengaged), for 5 / 15 / 30 min or Until I resume (= override_max_seconds, 2 h by default). You can start one from the Fan card grid, the tray or the keyboard. +5 min extends a running hold, and Resume curve ends it at once and re-seats the curve on the current temperature.

The daemon keeps watching the temperature during a hold. That is why holds go through the daemon instead of stopping it:

Rule What happens
Critical always wins At critical the fan goes to disengaged whatever the hold says.
Ceiling If T_fast ≥ override_ceiling_temp (82 °C) and the curve wants more airflow than the hold, the hold is suspended: mode hold_suspended, the curve level is used, one log line. It resumes only when T_slow < 82 − hysteresis = 76 °C and it has been suspended for at least 30 s. A single Tctl spike therefore cannot flip the fan back and forth. Holding Max is never suspended because nothing gives more airflow. Holding Firmware is not suspended either: the EC's own curve is running, and critical still overrides it.
No fan-off when warm A hold at 0 is refused (too_hot_for_fan_off) while the raw temperature is 55 °C or more, or unknown. The button is disabled with a tooltip.
Fan control unavailable A hold is refused (fan_control_unavailable) when /proc/acpi/ibm/fan has no commands: level … line, which means thinkpad_acpi is loaded without fan_control=1. It is never refused because of status: disabled, which only means the fan is at level 0 right now.
Bounded Every hold expires. The GUI shows the countdown and notifies you when a hold ends by itself.
Volatile Holds live in the daemon's memory. A daemon restart (including one by install.sh) or a reboot drops them.
Watchdog stays armed If the daemon dies during a hold, the EC still returns to auto.

Without the daemon the hold grid still works, through sudo fan-set-level.sh <level> 120: the EC watchdog is set to 120 s before every write, so a GUI that is killed hands the fan back within two minutes. While the GUI runs, a keep-alive thread rewrites the level every 30 s and checks the temperature every 2 s. At or above critical_temp (one sample is enough on this path) it writes disengaged instead (manual_critical). After the temperature has stayed below critical_temp − critical_exit_margin for 10 s and the critical hold time has passed, it hands the fan to firmware auto rather than back to the level that could not keep up. Three unreadable sensor samples, the hold expiring, Resume or quitting the app end it with auto; when the daemon comes back, the keep-alive stops and the daemon takes over. The dashboard calls this mode manual_unprotected and shows a red "no thermal protection" notice with a Start daemon button: there is no curve, no filtering and no ceiling on this path.

Modes in the status pill (and the tray): curve, hold, hold_suspended, critical, sensor_lost, and with the daemon down, firmware (fan on auto) or manual_unprotected.


6. Power limits (TDP and VRM current)

The 3500U is a 15 W part with a configurable range of 12–25 W. The Power view drives ryzenadj through ryzenadj-set-tdp.sh <watts> <vrm>:

  • Slider from 5 W to FANCTL_TDP_MAX, in zones: up to 15 W stock (teal), 16–25 W raised (amber), above 25 W beyond spec (red). Nothing is applied until you press Apply. Presets are Quiet 12 / Stock 15 / Boost 25 / Last used. The "Requested vs SMU reports" line shows when the firmware has quietly changed the limit back.
  • Ceilings come from /etc/thinkpad-fan-control/daemon.env: FANCTL_TDP_MAX=35 and FANCTL_TDP_MAX_VRM_UNLOCKED=30. The root wrapper refuses (exit 2) anything above them, and accepts only 5–40 written without leading zeros (010 would otherwise be read as octal 8). The backend refuses before it even calls the wrapper.
  • VRM current. Stock is EDC 45 A / TDC 35 A; unlocked is 60 A / 42 A. Both use --tctl-temp=95. What the UI calls "unlocked" is read from the hardware (ryzenadj --info reports an EDC limit of 55 A or more), not a remembered checkbox. Unlocking takes two clicks (arm, then confirm within 5 s), is never saved, and is reverted to stock when you quit the app or press Restore stock.
  • Keep limit applied (tdp_locked) re-applies the requested watts on a 5 s cycle when the SMU value drifts by 1 W or more, after a suspend/resume, or after a power-source change. It re-applies at most once every 20 s and is paused while the control temperature is at or above critical_temp − 3 (87 °C), so a TDP re-apply never works against a thermal event.
  • Apply at startup runs only if the previous session exited cleanly and the requested value is 25 W or less, and always uses stock VRM current. Otherwise the status says why it was skipped (unclean_exit or above_25w).

Freeze warning. When the SMU reports a limit of 30 W or more and the VRM current is unlocked (freeze_config_warning in /api/status), the TDP readout gets a warning icon and a banner says that this power configuration preceded the 2026-09-15 hang, not proven causal. That is the whole claim: on 2026-09-15 the machine froze with an amdgpu (GPU driver) hang during a DaVinci Resolve session while about 30 W and unlocked VRM current were applied. Nobody has shown that the power configuration caused it. Treat it as a known risky combination, not a forbidden one. FANCTL_TDP_MAX_VRM_UNLOCKED=30 is the hard limit, and Restore stock (or quitting the app) puts the VRM current back.

The SMU readouts (STAPM limit, PPT fast/slow, EDC, TDC, THM) come from sudo ryzenadj --info, read every 10 s while the window is visible and every 30 s while the app is in the tray. If ryzenadj fails, the last good values are kept and marked stale, smu.ok becomes false, and nothing is made up.


7. The simulator

The daemon's decision code can run against recorded or generated data, with a fake clock and a fake fan: no root, no hardware, no files under /run, no sound. This is how the defaults were chosen, and tests/sim/run.sh uses it to check them. Run it straight from the checkout:

D=daemon/thinkpad-fan-controld

# generate a 30-minute trace of a steady 15 W load (CSV on stdout)
python3 $D --gen-trace load15 --seconds 1800 --seed 7 > ~/load15.csv

# replay it through the real controller with the default config
python3 $D --simulate ~/load15.csv

# what-if: shorter dwell, one JSON summary line, no per-transition output
python3 $D --simulate ~/load15.csv --set dwell_down_s=30 --json --quiet

# the same trace under the v1 rules (raw thresholds, 5 °C hysteresis)
python3 $D --simulate ~/load15.csv --set legacy=1 --quiet

# replay what the live daemon saw in the last 30 minutes
python3 $D --simulate /run/thinkpad-fan-control/history.json

# start from your own config instead of the defaults
python3 $D --simulate ~/load15.csv --config /etc/thinkpad-fan-control/config.json
Option Meaning
--gen-trace SCENARIO print a generated trace: idle, load12, load15, load18 (steady loads of that many watts), stop (a heavy load that ends, to test the cool-down cascade), ramp (a scripted climb through critical to a 92–94 °C plateau and back), acflip (real AC changes plus one- and two-sample bounces), sensorloss, override (a hold at level 3 through a heat burst and a load that pushes past the ceiling)
--seconds N, --seed S trace length (default 3600, minimum 120) and random seed (default 1); the same seed always gives the same trace
--simulate TRACE a CSV trace or a history.json
--config FILE start from this config instead of the built-in defaults
--set key=value change one config key (repeatable; values are parsed as JSON, so --set watchdog=90, --set use_battery_curve=false); legacy=1 runs the v1 rules for comparison
--json print the summary as one JSON object
--quiet summary only, no transition lines
--detail with --json: include per-tick records, events and log lines
--open-loop replay recorded temperatures even if the trace has a power column

The generator uses a first-order thermal model (C = 50 J/K, ambient 36 °C, thermal resistance from 4.8 K/W at auto down to 2.25 K/W at disengaged, limited at 95 °C) plus Tctl bursts like the real ones: +5–14 °C for 1–3 s about every 25 s under load. Generated traces include the package power (p_w), so they replay closed loop: the simulated die temperature responds to the fan level the controller chooses, and a what-if config changes the temperatures too. A recorded trace has no power column and replays open loop: the recorded temperatures are used as they are, whatever the simulated fan does. That is good for counting decisions, not for judging cooling. ramp is scripted and always open loop.

A CSV needs ts (or t_s) and cpu (or tctl_c); igpu (or gpu_c), ac and sensor_ok are optional, and other columns are ignored. So tests/sim/traces/real-2026-09-23-mini-eq-1hz.csv (900 s of real 1 Hz data recorded on this machine under a one-core load) replays directly.

The summary reports changes_per_hour, transitions, median_dwell_s, min_dwell_s, min_gap_opposite_s (the shortest 7 → max → 7 style reversal), seconds_at_or_above_critical, time_share_per_level and alerts.

tests/sim/run.sh generates every scenario for seeds 1–10 (one hour each) and checks the mean across the seeds unless a rule says otherwise: idle ≤ 10 changes/h; load15 ≤ 30/h, with no single seed above 40 and no reversal closer than 10 s on any seed; load12 ≤ 10/h; stop makes its first DOWN step within 60 s of the load ending and never steps up during the cascade; ramp enters critical within two samples of the second reading at or above 90 °C, alerts exactly once per cooldown and exits only after the hold; acflip switches once per real change and ignores the bounces; sensorloss goes to auto after three missing samples with one log line and re-seats on recovery; override holds through 85 °C, is suspended above the ceiling, gives way to critical and re-seats on expiry. It also replays the real trace through the v2 controller and through the v1 rules and requires at least 3× fewer transitions. It prints a table and exits non-zero if any check fails. SIM_SEEDS="1 2 3", SIM_SECONDS=1800 and SIM_KEEP=1 (keep the work directory) change how it runs.


8. Keyboard shortcuts

In the dashboard:

Key Action
0 – 7 hold the fan at that level for the selected duration
M hold Max (disengaged)
F hold Firmware auto
R resume the curve
Ctrl+1 … Ctrl+4 views: Overview · Fan curve · Power · Log
? shortcut overlay
Esc close the overlay, cancel a curve-handle drag, or disarm a two-step button (such as VRM unlock or daemon stop/restart)

Shortcuts are ignored while you type in a field or while a curve handle has focus. Held-down keys do not repeat an action, and only one action runs at a time. In the curve editor a focused handle works like a slider: Left/Right move its temperature by 1 °C (5 °C with Shift), Up/Down change its level, and Delete removes the step (never the base step). While dragging a handle with the mouse, Shift snaps to 5 °C steps and Esc cancels the drag.


9. Where things live

Installed by install.sh:

Path Owner / mode Purpose
/usr/local/bin/thinkpad-fan-controld root 0755 the daemon (also --version, --save-config, --self-test, --simulate, --gen-trace)
/usr/local/bin/fan-set-level.sh root 0755 fan-set-level.sh <level> [watchdog]: direct EC write, used only while the daemon is not running
/usr/local/bin/fan-config-save.sh root 0755 exec thinkpad-fan-controld --save-config
/usr/local/bin/ryzenadj-set-tdp.sh root 0755 ryzenadj-set-tdp.sh <watts> <vrm>: TDP / VRM wrapper with the ceilings from daemon.env
/etc/thinkpad-fan-control/config.json root 0644 curves and thresholds; written only by the daemon
/etc/thinkpad-fan-control/daemon.env root 0644 FANCTL_GUI_UID, FANCTL_GUI_GID, FANCTL_GUI_HOME, FANCTL_GUI_RUNTIME_DIR, FANCTL_TDP_MAX, FANCTL_TDP_MAX_VRM_UNLOCKED
/etc/systemd/system/thinkpad-fan-control.service root 0644 the unit (Type=notify, sandboxed)
/etc/sudoers.d/fan-control root 0440 the wrappers, ryzenadj --info, and systemctl start/stop/restart of the unit
/etc/logrotate.d/thinkpad-fan-control root 0644 rotate at 2 MB, keep 2, compress
/etc/modprobe.d/thinkpad_acpi.conf root 0644 options thinkpad_acpi fan_control=1, written only if nothing else sets it
/run/thinkpad-fan-control/ root 0755 created by systemd while the daemon runs: state.json (0644), history.json (0644), control.sock (root:your group, 0660)
/var/lib/thinkpad-fan-control/rpm.json root 0644 learned RPM per level
/var/log/thinkpad-fan-control.log root 0644 the daemon log
/usr/local/share/thinkpad-fan-control/alert.wav root 0644 fallback alert sound
/var/backups/thinkpad-fan-control/<stamp>/ root everything an install replaced
~/.config/thinkpad-fan-control/settings.json you, 0600 (dir 0700) GUI settings: requested TDP, lock, apply at startup, hold duration, chart range, log filter, last view
~/Desktop/Fan Control.desktop, ~/.config/autostart/fan-control.desktop you launcher and autostart entry (tray mode)

In the checkout:

File What it is
daemon/thinkpad-fan-controld the daemon: standard-library Python only
daemon/thinkpad-fan-control.service, daemon/fan-control.sudoers, daemon/thinkpad-fan-control.logrotate, daemon/daemon.env.example files the installer installs or renders
daemon/fan-set-level.sh, daemon/fan-config-save.sh, ryzenadj-set-tdp.sh root wrappers
fanlib.py sensors, daemon client, SMU polling, TDP lock, HTTP API
app.py / server.py / launch.sh GTK app with tray / browser mode / launcher
index.html the dashboard, one self-contained file
install.sh / uninstall.sh §2
tests/ §11
docs/CONTRACT.md the specification

10. Troubleshooting

Start here

systemctl status thinkpad-fan-control.service
journalctl -u thinkpad-fan-control.service -n 50 --no-pager
tail -n 50 /var/log/thinkpad-fan-control.log
python3 -m json.tool /run/thinkpad-fan-control/state.json
cat /proc/acpi/ibm/fan

/proc/acpi/ibm/fan says status: disabled. This is not a problem and not the fan_control module option. thinkpad_acpi prints disabled whenever the EC fan register is 0, which means the fan is stopped at level 0 (for this driver, level 0 and disable are the same thing). You see it after a level-0 hold, a curve step at level 0, or echo level 0 / echo disable from another tool. Holds, Resume and the curve all keep working. Nothing in v2 (daemon, GUI, installer) treats status: disabled as "fan control off".

No commands: lines in /proc/acpi/ibm/fan. This is the real "fan control off": thinkpad_acpi was loaded without fan_control=1, so every write fails. With the option, the file ends with three lines: commands: level <level> …, commands: enable, disable and commands: watchdog <timeout> …. Check cat /sys/module/thinkpad_acpi/parameters/fan_control (it should print Y). install.sh writes options thinkpad_acpi fan_control=1 to /etc/modprobe.d/thinkpad_acpi.conf and asks for a reboot. Until then the daemon's self-test fails (the unit shows failed with a FATAL: self-test write … line), holds are refused with fan_control_unavailable, and the dashboard warns that fan control is unavailable. If the lines are still missing after a reboot, the module may be loaded from the initramfs, which does not see the new option: check with lsinitramfs /boot/initrd.img-$(uname -r) | grep thinkpad_acpi, and if it is there, run sudo update-initramfs -u and reboot.

The fan keeps going back to auto (firmware control). This is the EC watchdog doing its job: nothing wrote to the fan for watchdog seconds (60 by default). Either the daemon is stopped (systemctl start thinkpad-fan-control), or it hung and systemd's WatchdogSec=45 killed it. The journal shows that, and Restart=on-failure starts it again 5 s later. Without the daemon, a GUI hold renews the watchdog every 30 s; if the GUI was killed, the fan returns to auto within 120 s, which is intended. If the log says external fan write detected (level X), another program (thinkfan, a script, a manual echo level …) is writing to /proc/acpi/ibm/fan. The daemon writes its own level again, but two controllers fighting over the fan is a configuration mistake: use a hold instead of a manual write while the daemon runs.

Daemon dot is amber ("stale"). state.json exists but its timestamp is older than 3 × sample_interval + 2 seconds, so the daemon is still registered but has stopped publishing (blocked, or being killed). The dashboard keeps the last data, marks it stale and disables controls that need the daemon. The EC watchdog hands the fan to the firmware if the daemon stays silent, and systemd's watchdog restarts it. systemctl status and the journal tell you why.

Daemon dot is red / "Start daemon". /run/thinkpad-fan-control/ is gone because the unit is not running. Run sudo systemctl start thinkpad-fan-control, or use the button in the dashboard's Advanced section. If it stops again at once, the journal shows why: the self-test FATAL (see the commands: entry above), or FATAL: … not available after 60 s when k10temp/amdgpu never became readable. After 5 failures in 300 s systemd stops trying; fix the cause, then sudo systemctl reset-failed thinkpad-fan-control and start it again.

"Port in use — another copy is already running". Something already owns 127.0.0.1:7070, usually the GTK app sitting in the tray. It allows only one instance, so launching app.py again just raises its window, but server.py cannot share the port. Quit the tray app, or use another port: python3 server.py --port 7071. A different message, Cannot listen on 127.0.0.1:N, means the port number itself is not usable.

SMU unavailable / the Power view shows a placeholder. sudo ryzenadj --info failed or printed a table without STAPM LIMIT. Run it yourself to see the error; ryzenadj needs access to the SMU, which kernel lockdown under Secure Boot can block. The dashboard keeps the last good readout marked stale and offers Retry. It never makes up a value, and the TDP lock does nothing while smu.ok is false.

"Quit and relaunch Fan Control to pick up the new client". The installer found app.py or server.py from this checkout running. The daemon side is already upgraded, but the running GUI still uses the old page and library.

The installer rolled back. Either a step failed (the line and command are printed) or the post-check did not see an active unit with a fresh state.json within 10 s; the 20 journal lines it printed show the cause. Every file the run replaced was restored from /var/backups/thinkpad-fan-control/<stamp>/, files it created were removed, and the service was returned to its previous state. Fix the cause and run sudo ./install.sh again. A start that hangs is usually the daemon still waiting (up to 60 s) for /proc/acpi/ibm/fan or a readable sensor.

"REBOOT REQUIRED" at the end of the install. See the commands: entry above. Everything is installed and enabled; the daemon starts at the next boot. Until then the firmware drives the fan.

Autostart stays off after an upgrade. This is intended: the installer keeps X-GNOME-Autostart-enabled from the existing entry. Turn it on in Startup Applications or with the dashboard's autostart switch.

The installer warns about NOPASSWD: ALL. Your account has a sudo rule (outside this project, for example /etc/sudoers.d/90-<you>-nopasswd) that lets anything running as you become root without a password. While it exists, the narrow fan-control rules and the wrappers' argument checks protect nothing. Removing or narrowing that rule is your decision; Fan Control works either way.

No alert sound. The daemon plays alert_sound as your user through the PulseAudio/PipeWire socket in /run/user/<uid> (from daemon.env), trying paplay first and gst-play-1.0 if that fails. The file must be readable by you; otherwise the installed alert.wav plays. Use Test in Daemon & alerts (limited to one every 10 s) and look for a single WARN line in the log. Alerts fire only on a confirmed critical entry (two samples in a row at or above 90 °C, or one at 93 °C or above), so a one-second Tctl spike does not make a sound.

Logs. The daemon log is plain text with one [YYYY-mm-dd HH:MM:SS] message per line. logrotate rotates it at 2 MB and keeps two compressed generations. Identical warnings are written at most once a minute, with an (xN) count when they repeat. Level changes, config reloads, holds, critical entry and exit, alerts, power-source switches and sensor loss are logged; watchdog refreshes and per-sample data are not. Old logs can contain NUL bytes from hard crashes, and readers strip them. journalctl -u thinkpad-fan-control has the systemd side (start, stop, self-test, watchdog restarts).

Sensors show n/a. The hwmon device is missing. cat /sys/class/hwmon/*/name should list k10temp, amdgpu, thinkpad, nvme and iwlwifi_1. The controller needs at least one of k10temp or amdgpu; NVMe and Wi-Fi are only displayed.


11. Offline tests

None of these touch the real fan, sudo, systemd, /run or /etc:

tests/sim/run.sh                                             # controller acceptance (§7)
python3 -m unittest tests/test_daemon.py                     # daemon logic, config, socket
FANCTL_DRY_RUN=1 python3 -m unittest tests/test_fanlib_api.py -v   # backend API
python3 tests/mock_api.py --port 7150 --scenario hold       # dashboard against a fake backend

tests/test_daemon.py runs the daemon's decision code on its fake clock and fake fan, and starts the real binary only with every path redirected to a temporary directory and a fake fan file. It refuses to run as root, because the daemon ignores those redirections when it is root.

FANCTL_DRY_RUN=1 makes the backend skip every sudo, socket and sound action and report it as successful; sensor reads stay real. Test servers use ports 7100–7199 so they never clash with a running dashboard on 7070. tests/mock_api.py serves index.html with simulated data for scenarios such as curve, hold, critical, daemon_down, manual_unprotected, stale, smu_missing, sensor_lost, freeze and battery (the list is in the file's header). It is a development aid with its own simplified controller, not a reference for daemon behaviour.

12. License