Add ESG Service EPG selector consistency check (CSCwv51642) - #506

Open
gautvenk wants to merge 1 commit into
datacenter:v4.3.1-devfrom
gautvenk:CSCww77700-esg-lifctx-consistency
Open

gautvenk wants to merge 1 commit into
datacenter:v4.3.1-devfrom
gautvenk:CSCww77700-esg-lifctx-consistency

Conversation

@gautvenk

Copy link
Copy Markdown

Adds esg_lifctx_selector_consistency_check for CSCwv51642.

Service EPGs (vnsLIfCtx) that use the same L4-L7 device and BD share one pcTag, so they must be selected by the same ESG (or none). Before 6.3(1), APIC validated only the provider-side Service EPG of a device selection policy, so a consumer-side Service EPG with a different ESG was accepted. Starting with 6.3(1), the consumer side is validated too, and changing an ESG selector re-renders every graph sharing the device and BD. After the upgrade, the next re-render of such a graph (post-upgrade processing or a configuration change) raises F1690 (lifctx-should-have-same-esg) / F0758, and the graph goes to failed-to-apply.

  • Runs when the target is 6.3(1) or later and the current release is 5.2(4) (Service EPG selector introduced) or later. Current releases already on 6.3(1)+ are checked too, because an affected graph stays applied until a re-render, which the upgrade can trigger. MANUAL without a target version.
  • Mirrors APIC: only device selection policies whose two Service EPGs are both on a BD, only the consumer-side Service EPG, compared against every Service EPG (consumer or provider, any graph) on the same vnsLDevVip + BD, including devices and BDs shared from tenant common.
  • Not reported (no new fault after the upgrade): provider-side-only mismatches, device selection policies with a Service EPG without a BD (L3Out), imported devices (vnsLDevIf).
  • Returns FAIL - OUTAGE WARNING!! with one row per affected graph: consumer-side Service EPG, its ESG, and the other ESGs on the device/BD.
  • 3 flat class queries: fvLIfCtxSelector, vnsRsLIfCtxToBD, vnsRsLIfCtxToLIf.
  • Docs: summary row d47 and a details section referencing the ACI PBR Service Graph Whitepaper. The check is ordered before the App Center check.

Verification:

  • 14 focused tests pass on Python 2.7 and 3.8; 1,473 tests pass on Python 3.8 after rebasing on v4.3.1-dev.
  • Live run on an APIC simulator (build with the fix; check run as 6.1(2f) → 6.3(1a) against live data):
    • 3 contracts sharing one device and BD, ESG on one consumer-side Service EPG: APIC failed-to-apply ×3 (F1690/F0758); check FAIL, 3 rows.
    • Same, ESG on one provider-side Service EPG only: APIC failed-to-apply ×3 (pre-existing behavior); check PASS.
    • 2 contracts in one tenant sharing a tenant-common device and BD, ESG on one consumer-side Service EPG: APIC failed-to-apply ×2; check FAIL, 2 rows.
    • No selectors: APIC applied; check PASS.
  • GitLab integration has not run.

Starting with 6.3(1), APIC also validates the consumer-side Service EPG
(vnsLIfCtx) of a device selection policy whose two Service EPGs are on a
BD, and re-renders every graph sharing the device and BD when an ESG
selector changes (CSCwv51642). A consumer-side Service EPG whose ESG
selection differs from another Service EPG on the same device and BD was
accepted before and fails to apply (F1690/F0758) on the next re-render
after the upgrade.

Tracked by CSCww77700.