This project outlines a rigorous protocol for generating a standardized EEG dataset. The resulting data is engineered for high-performance applications in computational neuroscience and machine learning, specifically targeting:
- Brain-Computer Interfaces (BCI)
- Deep Learning Research (CNNs, LSTMs, Transformers)
The setup follows global neuroimaging standards to ensure the dataset is interoperable, reproducible, and ready for public research distribution.
- Scalable Design: Create a clean, modular EEG experimental pipeline.
- Multi-Subject Collection: Acquire diverse data across a broad subject pool.
- Standardization: Adhere to BIDS and IFCN guidelines for seamless data sharing.
- AI-Ready: Provide structured, well-labeled data for immediate ML/DL model training.
This protocol adheres to the following international frameworks:
| Standard | Description | Reference |
|---|---|---|
| IFCN Guidelines | Clinical and research EEG recording standards | Clinical Neurophysiology |
| EEG-BIDS | Brain Imaging Data Structure for EEG | BIDS Specification |
| ERP Design | Principles for Event-Related Potential techniques | Luck (2014) |
The protocol supports research-grade and "prosumer" mobile EEG devices:
We utilize the International 10–20 System to ensure consistent spatial mapping across subjects.
To maintain high signal fidelity, the following parameters are enforced:
- Sampling Rate: 250–500 Hz
-
Resolution:
$\ge$ 16-bit -
Electrode Impedance:
$< 5$ k$\Omega$ - Hardware Filter: 50 Hz Notch filter (Power-line noise removal)
- Age: 18–40 years.
- Health: Healthy individuals with no history of neurological or psychiatric disorders.
- Caffeine: Avoid intake 2–3 hours prior to the session.
- Rest: Minimum 7–8 hours of sleep the previous night.
- Physical: Removal of all metallic jewelry/accessories.
- Full informed consent obtained from all participants.
- Data is strictly anonymized using unique Subject IDs (e.g.,
sub-01). - Reference: WHO Research Ethics
Each session is divided into three distinct phases:
Establishment of "Resting State" EEG activity (Eyes Open/Eyes Closed).
- Stimulus Duration: 30–60 seconds.
- Rest Interval: 10–15 seconds.
- Trials: 10–30 repetitions per condition.
- Tasks: Musical stimuli, visual tracking, cognitive problem-solving.
Post-trial subjective feedback including:
- Emotion: Valence (Pleasure) and Arousal (Excitement).
- Workload: Task difficulty and attention levels.
The data follows the BIDS-inspired directory hierarchy:
dataset/
├── sub-01/
│ ├── eeg/
│ │ ├── raw_eeg.csv # Time-series voltage data
│ │ ├── events.csv # Stimulus markers and timestamps
│ ├── labels.json # Self-assessment scores
│ └── metadata.json # Device and session info
├── sub-02/
...
{
"sampling_rate": 250,
"channels": ["F3", "F4", "T7", "T8"],
"experiment_type": "emotion",
"stimulus": "music"
}- Band-pass filter: 0.5–45 Hz
- Notch filter: 50 Hz
- Artifact removal using ICA
Reference:
https://mne.tools/stable/index.html
- Delta (0.5–4 Hz)
- Theta (4–8 Hz)
- Alpha (8–13 Hz)
- Beta (13–30 Hz)
- Gamma (>30 Hz)
- Power Spectral Density (PSD)
- Differential Entropy
- Hjorth Parameters
- Wavelet Transform
- Support Vector Machine (SVM)
- Random Forest
- Convolutional Neural Networks (CNN)
- Long Short-Term Memory (LSTM)
-
EEGNet (Compact CNN for EEG)
https://arxiv.org/abs/1611.08024 -
Deep Learning Review
https://www.sciencedirect.com/science/article/pii/S0957417419302743
https://www.eecs.qmul.ac.uk/mmv/datasets/deap/
Paper: https://ieeexplore.ieee.org/document/5871728
http://bcmi.sjtu.edu.cn/~seed/
Paper: https://ieeexplore.ieee.org/document/7104132
https://physionet.org/content/eegmmidb/1.0.0/
https://www.isip.piconepress.com/projects/tuh_eeg/html/downloads.shtml
Recommended platforms:
-
Zenodo (DOI generation)
https://zenodo.org/ -
PhysioNet
https://physionet.org/
- Maintain consistent experimental conditions
- Minimize noise and movement artifacts
- Ensure accurate and consistent labeling
- Validate data quality before publishing
- Provide baseline ML model results
- EEG signals are highly sensitive to noise
- Subject variability affects consistency
- Limited spatial resolution compared to fMRI
Specify dataset license before publishing.
Recommended options:
- MIT License
- CC BY 4.0