Skip to content

fix: retain samples in the database guide's capped fits - #465

Merged
Jammy2211 merged 1 commit into
mainfrom
feature/database-guide-sample-weight-threshold
Aug 4, 2026
Merged

Jammy2211 merged 1 commit into
mainfrom
feature/database-guide-sample-weight-threshold

Conversation

@Jammy2211

Copy link
Copy Markdown
Collaborator

Closes #464.

scripts/guides/results/database/start_here.py fails with IndexError: list index out of range at line 358 (samples.parameter_lists[9][2]) in PyAutoHeart's release-integrate leg — run 30880450685, job integrate / run_scripts (3.12, autolens, guides), FAIL at 129.9s.

Cause

The script runs its own two Nautilus fits capped at n_like_max=300, then indexes sample 9. PyAutoFit/autofit/non_linear/samples/samples.py:398 applies config/output.yaml's samples_weight_threshold: 1.0e-10 when writing samples.csv, and a 300-evaluation nested-sampling run is so weight-peaked that only one sample clears it.

This is the same family as #274 / PyAutoFit#275 (release-validation cluster E). That fix consolidated the other guides/results tutorials onto _quick_fit.py, which sets the threshold to None at line 57 for exactly this reason — but this script was left out, because it must build a database from its own output folder over two differently-named datasets, which is the tutorial's subject.

Not a regression

e41b0fce added the auto-simulate guard to this script and removed its NEEDS_FIX entry from config/build/no_run.yaml. Yesterday's release run executed 41 scripts in the guides shard; today's executed 42. The script ran for the first time and hit a pre-existing defect.

The fix

conf.instance["output"]["samples_weight_threshold"] = None before the fit loop, with a short prose section explaining that the 300-evaluation cap is what makes the pruning bite and that a full-length fit does not need the line. Line 358 is unchanged — indexed sample access is the tutorial's subject, and the sibling results guides (aggregator/samples.py:200, aggregator/samples_via_aggregator.py:146) index [9] identically.

⚠️ Smoke cannot verify this fix

profile_smoke.yaml sets PYAUTO_SKIP_CHECKS=1, and samples.py:402 reads that as if skip_checks(): weight_threshold = None — the smoke profile disables the very threshold that causes the failure. A green smoke run on this PR is not evidence. The real gate is PyAutoHeart's release-integrate leg.

profile PYAUTO_SKIP_CHECKS threshold rows in samples.csv result
smoke 1 disabled 301 PASS
release 0 1e-10 1 FAIL

Evidence — control vs patched, both under profile_release.yaml

Run via autohands.env_config.build_env_for_script against config/build/profile_release.yaml, from a clean slate deleting output/database/, output/database.sqlite and output/database.info.

Control (unchanged script, main):

EXIT 1
  File ".../scripts/guides/results/database/start_here.py", line 358, in <module>
    print(samples.parameter_lists[9][2], "\n")
IndexError: list index out of range
     1 data rows  [TOO FEW]  database/simple/.../files/samples.csv
     1 data rows  [TOO FEW]  database/simple__no_lens_light/.../files/samples.csv

Patched (this branch):

EXIT 0
   300 data rows  [ok]  database/simple/.../files/samples.csv
   300 data rows  [ok]  database/simple__no_lens_light/.../files/samples.csv

The control reproduces the CI traceback line-for-line.

Scripts Changed

  • scripts/guides/results/database/start_here.py — import conf, disable samples_weight_threshold before the fit loop, and add a __Sample Retention__ prose section explaining why

No pending-release label: this is workspace-only and depends on no unreleased library API, so there is no library-first merge gate (same as #461, #463 and #450).

Note for anyone reproducing this

output/database.sqlite sits beside output/database/, so rm -rf output/database does not clear it and the aggregator silently reads the previous run's entries. That produced a false pass during diagnosis. A clean slate must delete the directory, the .sqlite and the .info.

Notebooks regenerated.

🤖 Generated with Claude Code

scripts/guides/results/database/start_here.py indexes sample 9 of the two
Nautilus fits it runs itself, but those fits are capped at n_like_max=300 and
the config/output.yaml samples_weight_threshold of 1e-10 prunes samples.csv to
a single row, so the index raised IndexError under the release profile.

Disable the threshold before the fits, as _quick_fit.py already does for the
other results guides, with a prose section explaining that the cap is what
makes the pruning bite.

The smoke profile sets PYAUTO_SKIP_CHECKS=1, which disables the threshold
outright, so smoke cannot reproduce this failure class.

Closes #464

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
@Jammy2211
Jammy2211 merged commit ec82b6b into main Aug 4, 2026
5 checks passed
@Jammy2211
Jammy2211 deleted the feature/database-guide-sample-weight-threshold branch August 25, 2026 18:56