Skip to content
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
6 changes: 3 additions & 3 deletions autolens/point/fit/abstract.py
Original file line number Diff line number Diff line change
Expand Up @@ -115,9 +115,9 @@ def magnifications_at_positions(self) -> aa.ArrayIrregular:

These magnifications are used for two purposes:

1) For a source-plane chi-squared calculation, the residuals are multiplied by the magnification to account for
how the noise in the image-plane positions is magnified to the source-plane, thus defining a
better chi-squared.
1) For the opt-in `weighting = "magnification"` source-plane chi-squared, the residuals are multiplied by the
magnification to approximate how the noise in the image-plane positions maps to the source-plane (the
default `"jacobian"` weighting uses the full lensing Jacobian instead).

2) For fitting the fluxes of point sources, the magnification is used to scale the flux of the point source
in the source-plane to the image-plane, thus computing the model image-plane fluxes.
Expand Down
92 changes: 39 additions & 53 deletions autolens/point/fit/positions/source/separations.py
Original file line number Diff line number Diff line change
Expand Up @@ -30,11 +30,13 @@

class FitPositionsSource(AbstractFitPositions):
#: How each back-traced position's residual from the source-plane centre is weighted:
#: `"magnification"` — the traditional scalar `µᵢ²/σᵢ²` weighting with the magnified-noise
#: normalization (the long-standing behaviour of this class, and the Lenstool convention);
#: `"jacobian"` — the per-image precision tensor `Wᵢ = Aᵢ⁻ᵀΘᵢAᵢ⁻¹` with the observed-plane
#: normalization, matching `FitPositionsSourceSolved` but with the centre a free parameter.
weighting = "magnification"
#: `"jacobian"` (the default) — the per-image precision tensor `Bᵢ = Aᵢ⁻ᵀΘᵢAᵢ⁻¹`, so each residual is
#: measured in the image-plane noise ellipse (the Gravity.jl source-plane likelihood, Lombardi 2024
#: Eq. 46; Keeton 2001 Eq. 10; Lenstool's tensor mode, `forme 8`);
#: `"magnification"` (opt-in only) — the scalar isotropic approximation `Bᵢ ≈ (µᵢ²/σᵢ²) I₂` of
#: Jullo et al. 2007 Eq. 10, which is biased near critical curves (see `__init__`).
#: Both use the same model-independent normalization `Σᵢ log((2π)² σᵢ⁴)`.
weighting = "jacobian"

def __init__(
self,
Expand Down Expand Up @@ -63,22 +65,28 @@ def __init__(

3) Compute the distance of each ray-traced position to the source-plane centre and compute the residuals,

4) Compute the magnification of each image-plane position via the Hessian of the tracer's deflection angles.
4) Compute the lensing Jacobian `Aᵢ` of each image-plane position via the Hessian of the tracer's
deflection angles.

5) Compute the residuals of each position as the difference between the source-plane centre and each
ray-traced position.
5) Compute the residual vector `δᵢ = β̂ᵢ − c` of each position, the difference between each ray-traced
position `β̂ᵢ` and the source-plane centre `c`.

6) Compute the chi-squared of each position as the square of the residual multiplied by the magnification and
divided by the RMS noise-map value.
6) Compute the chi-squared of each position as `δᵢᵀ Bᵢ δᵢ`, with the precision tensor `Bᵢ = Aᵢ⁻ᵀΘᵢAᵢ⁻¹`
(`Θᵢ = σᵢ⁻² I₂`, see `autolens.point.fit.solved.precision_tensor_components_from`), so each residual is
measured in the image-plane noise ellipse.

7) Sum the chi-squared values to compute the overall log likelihood of the fit.
7) Sum the chi-squared values and the model-independent noise normalization `Σᵢ log((2π)² σᵢ⁴)` to
compute the overall log likelihood of the fit.

Steps 4-6 describe the default `weighting = "magnification"` scalar convention. Setting the
`weighting` class attribute to `"jacobian"` instead weights each vector residual `β̂ᵢ − c` (with `c`
the profile's free `centre`) by the per-image precision tensor `Wᵢ = Aᵢ⁻ᵀΘᵢAᵢ⁻¹` (see
`autolens.point.fit.solved.precision_tensor_components_from`), with the observed-plane noise
normalization matching `FitPositionsSourceSolved` — the same tensor likelihood as that class, but
with the centre sampled as a free parameter rather than solved and marginalized.
Steps 4-6 describe the default `weighting = "jacobian"`. This is the Gravity.jl source-plane likelihood
(Lombardi 2024, arXiv:2406.15280, Eq. 46; its marginalised-source form, Eq. 58, is
`FitPositionsSourceSolved`), Keeton 2001 Eq. 10, and Lenstool's tensor mode (`forme 8`). It stays
robust near critical curves and costs nothing extra over the scalar magnification.

Setting the `weighting` class attribute to `"magnification"` instead uses the scalar isotropic
approximation `Bᵢ ≈ (µᵢ²/σᵢ²) I₂` of Jullo et al. 2007 Eq. 10, i.e. `χ²ᵢ = |δᵢ|² µᵢ²/σᵢ²`. This is exact
only along the tangential direction and for a radial eigenvalue of 1. Near critical curves it
over-weights the radial direction by about `µ²`, so it is biased, and it is provided as an opt-in only.

Point source fitting uses name pairing, whereby the `name` of the `Point` object is paired to the name of the
point source dataset to ensure that point source datasets are fitted to the correct point source.
Expand Down Expand Up @@ -167,9 +175,9 @@ def chi_squared_map(self) -> float:
"""
Returns the chi-squared of the point-source source-plane fit.

For `weighting = "magnification"` this is the squared residuals multiplied by the magnifications
squared, divided by the noise-map values squared. For `weighting = "jacobian"` it is the per-image
quadratic form `(β̂ᵢ−c)ᵀ Wᵢ (β̂ᵢ−c)` with the precision tensor `Wᵢ = Aᵢ⁻ᵀΘᵢAᵢ⁻¹`.
For the default `weighting = "jacobian"` it is the per-image quadratic form `(β̂ᵢ−c)ᵀ Bᵢ (β̂ᵢ−c)` with the
precision tensor `Bᵢ = Aᵢ⁻ᵀΘᵢAᵢ⁻¹`. For the opt-in `weighting = "magnification"` this is the squared
residuals multiplied by the magnifications squared, divided by the noise-map values squared.
"""
if self.weighting == "magnification":
return self.residual_map**2.0 / (
Expand All @@ -190,26 +198,13 @@ def chi_squared_map(self) -> float:
@property
def noise_normalization(self) -> float:
"""
Returns the noise normalization of the fit's Gaussian likelihood.
Returns the noise normalization of the fit's Gaussian likelihood, `Σᵢ log((2π)² σᵢ⁴)`.

For `weighting = "magnification"` this is the long-standing magnified-noise source-plane-data
convention `Σᵢ log(2π µᵢ⁻²σᵢ²)`. For `weighting = "jacobian"` it is the observed-plane
(model-independent) convention `Σᵢ log((2π)² σᵢ⁴)` matching `FitPositionsSourceSolved` (see that
class's docstring for why a model-dependent normalization would spuriously favour
high-magnification models).
This is the observed-plane (model-independent) normalization of the 2-D Gaussian over each image
position (Lombardi 2024 Eq. 46, `log|Θᵢ/2π|`), used for both weightings: for `"magnification"` it is
Eq. 46 with `Bᵢ ≈ µᵢ²Θᵢ`. A model-dependent normalization (e.g. `log det Bᵢ`, or the 1-D
`Σᵢ log(2π σᵢ²/µᵢ²)`) would spuriously favour high-magnification models.
"""
if self.weighting == "magnification":
return self._xp.sum(
self._xp.log(
2
* np.pi
* (
self.magnifications_at_positions.array**-2.0
* self.noise_map.array**2.0
)
)
)

sigma_sq = self.noise_map.array**2.0
return self._xp.sum(self._xp.log((2.0 * np.pi) ** 2.0 * sigma_sq**2.0))

Expand All @@ -229,8 +224,10 @@ class FitPositionsSourceSolved(SolvedCentre, FitPositionsSource):
The lens equation is Taylor-expanded around each observed image position `θ̂ᵢ`, giving a source-plane
position that is linear in the per-image back-traced position `β̂ᵢ` (`SolvedCentre._beta_hat`, computed the
same way as `FitPositionsSource.model_data`) and the per-image precision `Wᵢ` (`weighting = "jacobian"` by
default — the tensor weighting `Wᵢ = Aᵢ⁻ᵀΘᵢAᵢ⁻¹`; set `weighting = "magnification"` for the scalar
`Wᵢ = (µᵢ²/σᵢ²) I₂` weighting used by `FitPositionsSource`, for Lenstool-style comparisons). This makes the
default, as for `FitPositionsSource` — the tensor weighting `Wᵢ = Aᵢ⁻ᵀΘᵢAᵢ⁻¹`; set
`weighting = "magnification"` for the opt-in scalar `Wᵢ = (µᵢ²/σᵢ²) I₂` approximation of Jullo et al. 2007
Eq. 10, which is biased near critical curves). This is the marginalised-source likelihood of Lombardi 2024
Eq. 58. This makes the
source-plane centre solvable in closed form (`SolvedCentre.source_plane_coordinate`, `β*`), and the
likelihood analytically marginalizes over it (flat prior):

Expand All @@ -243,9 +240,8 @@ class FitPositionsSourceSolved(SolvedCentre, FitPositionsSource):
The normalization deliberately uses the observed-plane precision `Θᵢ` (model-independent), NOT `det Wᵢ`:
this is a likelihood of the *observed image-plane positions* under the linearized lens equation (Lombardi
2024 Eq. 46), so the Gaussian normalization is over the data space. A `det Wᵢ` normalization would add
`-2Σᵢ log|µᵢ|`-like model-dependent terms that spuriously favour high-magnification models. (The
long-standing `FitPositionsSource` uses the magnified-noise source-plane-data convention instead — its
normalization is intentionally unchanged.)
`-2Σᵢ log|µᵢ|`-like model-dependent terms that spuriously favour high-magnification models. The same
normalization is used for both weightings, and is inherited from `FitPositionsSource`.

Must be paired (by name) with a parameter-free profile such as `ag.ps.PointSolved`: a `centre`-bearing
profile (`ag.ps.Point` / `ag.ps.PointFlux`) raises (see `SolvedCentre.source_plane_coordinate`), since its
Expand Down Expand Up @@ -287,16 +283,6 @@ def chi_squared(self) -> float:
"""
return self._xp.sum(self.chi_squared_map.array)

@property
def noise_normalization(self) -> float:
"""
`noise_norm = Σᵢ log((2π)² / det Θᵢ) = Σᵢ log((2π)² σᵢ⁴)` — the observed-plane (model-independent)
Gaussian normalization of the linearized image-plane likelihood (see class docstring; NOT `det Wᵢ`,
which would spuriously favour high-magnification models).
"""
sigma_sq = self.noise_map.array**2.0
return self._xp.sum(self._xp.log((2.0 * np.pi) ** 2.0 * sigma_sq**2.0))

@property
def marginalization_term(self) -> float:
"""
Expand Down
27 changes: 17 additions & 10 deletions autolens/point/fit/solved.py
Original file line number Diff line number Diff line change
Expand Up @@ -34,10 +34,15 @@
the tensor is exact in every regime: isotropically each stretch is `√µ` (giving `µᵢ/σᵢ²`),
while near a critical curve the tangential stretch is `≈ µ` (giving `µᵢ²/σᵢ²` along the arc).

The `weighting = "magnification"` class-attribute option instead uses the scalar weighting
`Wᵢ = (µᵢ²/σᵢ²) I₂` already used by `FitPositionsSource.chi_squared_map` — the traditional
Lenstool-style approximation, which coincides with the tensor only in the near-critical
tangential limit (NOT isotropically) — retained for comparisons with that convention.
This tensor weighting (`weighting = "jacobian"`, the default of both `FitPositionsSource` and
`FitPositionsSourceSolved`) measures each source-plane residual in the image-plane noise ellipse.
It is the Gravity.jl source-plane likelihood (Lombardi 2024 Eq. 46; marginalised source Eq. 58),
Keeton 2001 Eq. 10, and Lenstool's tensor mode (`forme 8`).

The opt-in `weighting = "magnification"` class-attribute option instead uses the scalar isotropic
weighting `Wᵢ = (µᵢ²/σᵢ²) I₂` of Jullo et al. 2007 Eq. 10. It is exact only tangentially and for a
radial eigenvalue of 1; near critical curves it over-weights the radial direction by about `µ²`,
so it is biased.

The solved source-plane centre is then the precision-weighted mean of the per-image
back-traced positions `β̂ᵢ`:
Expand Down Expand Up @@ -97,10 +102,12 @@ def precision_tensor_components_from(fit, weighting: str) -> Tuple:
The point-source fit object (any `AbstractFitPositions` subclass) providing `positions`, `tracer`,
`name`, `noise_map` and `_xp`.
weighting
`"jacobian"` — the tensor weighting `Wᵢ = Aᵢ⁻ᵀΘᵢAᵢ⁻¹`, with `Aᵢ` the lensing Jacobian at the observed
position (see module docstring).
`"magnification"` — the traditional scalar weighting `Wᵢ = (µᵢ²/σᵢ²) I₂`, matching
`FitPositionsSource.chi_squared_map` (the near-critical tangential limit of the tensor).
`"jacobian"` (the default) — the tensor weighting `Wᵢ = Aᵢ⁻ᵀΘᵢAᵢ⁻¹`, with `Aᵢ` the lensing Jacobian at
the observed position, so each residual is measured in the image-plane noise ellipse (Lombardi 2024
Eq. 46; Keeton 2001 Eq. 10; Lenstool `forme 8`; see module docstring).
`"magnification"` (opt-in) — the scalar isotropic approximation `Wᵢ = (µᵢ²/σᵢ²) I₂` of Jullo et al.
2007 Eq. 10, exact only tangentially and for a radial eigenvalue of 1; near critical curves it
over-weights the radial direction by about `µ²`, so it is biased.
"""
xp = fit._xp
precision_scalar = _as_array(fit.noise_map) ** -2.0 # Θ = σ⁻² I
Expand All @@ -114,8 +121,8 @@ def precision_tensor_components_from(fit, weighting: str) -> Tuple:
if weighting != "jacobian":
raise exc.PointProfileMismatchException(
f"Unsupported weighting '{weighting}' for the source-plane position residuals. "
f"Valid options are 'jacobian' (tensor weighting, the default of the *Solved fit classes) or "
f"'magnification' (scalar isotropic weighting, the default of `FitPositionsSource`)."
f"Valid options are 'jacobian' (tensor weighting, the default) or "
f"'magnification' (opt-in scalar isotropic weighting)."
)

lens_calc = _lens_calc_for(fit)
Expand Down
2 changes: 1 addition & 1 deletion autolens/point/plot/source_plane_panel.py
Original file line number Diff line number Diff line change
Expand Up @@ -130,7 +130,7 @@ def presentation_from(fit_positions) -> SourcePlanePresentation:
Returns how the source-plane panel presents a positions fit, paired to its class.

The class is looked up in :func:`presentation_table` along its method resolution order, so a user subclass of a
fit class (e.g. ``FitPositionsSource`` with ``weighting = "jacobian"``) is presented as its parent. The weighting
fit class (e.g. ``FitPositionsSource`` with ``weighting = "magnification"``) is presented as its parent. The weighting
of a source-plane fit is read from the fit itself. A class with no entry is presented as context only, which
never draws a chi-squared the fit may not compute.
"""
Expand Down
84 changes: 77 additions & 7 deletions test_autolens/point/fit/positions/source/test_separations.py
Original file line number Diff line number Diff line change
Expand Up @@ -22,8 +22,12 @@ def test__fit_positions_source__all_residual_quantities_correct_without_mass_pro
assert fit.normalized_residual_map.in_list == [1.0 / 0.5, 2.0 / 1.0]
assert fit.chi_squared_map.in_list == [(1.0 / 0.5) ** 2.0, 2.0 ** 2.0]
assert fit.chi_squared == pytest.approx(8.0, 1.0e-4)
assert fit.noise_normalization == pytest.approx(2.28945, 1.0e-4)
assert fit.log_likelihood == pytest.approx(-5.14472988, 1.0e-4)
# Σᵢ log((2π)² σᵢ⁴) = 2 log(4π²) + 4 log(0.5); with no mass A = I, so jacobian χ² = magnification χ².
assert fit.noise_normalization == pytest.approx(
2.0 * np.log(4.0 * np.pi**2) + 4.0 * np.log(0.5), 1.0e-8
)
assert fit.noise_normalization == pytest.approx(4.57891954, 1.0e-6)
assert fit.log_likelihood == pytest.approx(-6.28945977, 1.0e-6)


def test__fit_positions_source__with_isothermal_mass_profile__magnification_reduces_source_positions():
Expand All @@ -48,10 +52,27 @@ def test__fit_positions_source__with_isothermal_mass_profile__magnification_redu
[1.1111049387688177, 1.0526308864400329], 1.0e-4
)
assert fit.model_data.in_list == [(0.0, 0.9), (0.0, 1.9)]
assert fit.chi_squared_map.in_list == pytest.approx(
[3.9999555592589244, 3.9999947369459807], 1.0e-4

# The residuals (0, r - 0.1) are radial, and the radial eigenvalue of an isothermal Jacobian is 1, so
# the default jacobian χ²ᵢ = (r - 0.1)² / σᵢ², i.e. (0.9 / 0.5)² and 1.9².
assert fit.chi_squared_map.in_list == pytest.approx([3.24, 3.61], 1.0e-6)
noise_normalization = 2.0 * np.log(4.0 * np.pi**2) + 4.0 * np.log(0.5)
assert fit.log_likelihood == pytest.approx(
-0.5 * (3.24 + 3.61 + noise_normalization), 1.0e-6
)
assert fit.log_likelihood == pytest.approx(-5.71445977, 1.0e-6)

# The opt-in scalar weighting multiplies by µᵢ² = 1 / (1 - 0.1 / r)², over-weighting the radial
# residual: χ²ᵢ = (r - 0.1)² µᵢ² / σᵢ² = r² / σᵢ² = 4 for both, with the same normalization.
fit = FitPositionsSourceMagnification(
name="point_0", data=positions, noise_map=noise_map, tracer=tracer, solver=None
)

assert fit.chi_squared_map.in_list == pytest.approx([4.0, 4.0], 1.0e-4)
assert fit.noise_normalization == pytest.approx(noise_normalization, 1.0e-8)
assert fit.log_likelihood == pytest.approx(
-0.5 * (8.0 + noise_normalization), 1.0e-5
)
assert fit.log_likelihood == pytest.approx(-4.98805743691215, 1.0e-4)


def test__fit_positions_source__multi_plane_tracer__model_data_traces_to_correct_source_plane():
Expand Down Expand Up @@ -84,8 +105,57 @@ class FitPositionsSourceJacobian(al.FitPositionsSource):
weighting = "jacobian"


def test__fit_positions_source__default_weighting_is_magnification():
assert al.FitPositionsSource.weighting == "magnification"
class FitPositionsSourceMagnification(al.FitPositionsSource):
weighting = "magnification"


def test__fit_positions_source__default_weighting_is_jacobian():
assert al.FitPositionsSource.weighting == "jacobian"


def test__fit_positions_source__jacobian__true_model_outranks_perturbed_models_near_critical():
"""
An elliptical power law with slope 2.3 (so the radial eigenvalue of the Jacobian is not 1) and a quad of
images traced exactly from the source centre, with magnifications up to ~17. Under the default jacobian
weighting the true model must have a higher log likelihood than small perturbations of it.
"""
source_centre = (0.05, 0.0)

positions = al.Grid2DIrregular(
[
(0.947716092108, -0.370287233244),
(-0.50956321869, 0.809453183983),
(-0.69058165779, -0.617211899037),
(0.043787760967, 0.960520345829),
]
)
noise_map = al.ArrayIrregular([0.005, 0.005, 0.005, 0.005])

def fit_from(einstein_radius=1.0, centre=(0.0, 0.0)):
mass = al.mp.PowerLaw(
centre=centre, ell_comps=(0.1, 0.05), einstein_radius=einstein_radius, slope=2.3
)
tracer = al.Tracer(
galaxies=[
al.Galaxy(redshift=0.5, mass=mass),
al.Galaxy(redshift=1.0, point_0=al.ps.Point(centre=source_centre)),
]
)
return al.FitPositionsSource(
name="point_0", data=positions, noise_map=noise_map, tracer=tracer, solver=None
)

fit_true = fit_from()

assert np.max(fit_true.magnifications_at_positions.array) > 10.0
assert fit_true.chi_squared == pytest.approx(0.0, abs=1.0e-4)

for fit_perturbed in [
fit_from(einstein_radius=1.01),
fit_from(centre=(0.005, 0.0)),
fit_from(centre=(0.0, 0.005)),
]:
assert fit_true.log_likelihood > fit_perturbed.log_likelihood


def test__fit_positions_source__jacobian_weighting__matches_solved_at_solved_centre():
Expand Down
Loading
Loading