Repository navigation
Description
Bug
autolens/analysis/latent.py::total_source_flux_mujy (shipped in #534) returns wrong values for fits using linear light profiles (any lp_linear.* or MGE basis).
def total_source_flux_mujy(fit, magzero, xp=np):
...
source_image = fit.tracer.galaxies[-1].image_2d_from(
grid=fit.dataset.grids.lp, xp=xp
)For linear light profiles, fit.tracer.galaxies[-1] has unsolved profiles (the inversion fills intensities at fit time, but fit.tracer doesn't apply them). image_2d_from returns zeros / garbage.
Transitively breaks magnification too (numerator uses galaxy_image_dict which IS correct for linear; denominator is the broken image_2d_from).
The euclid pipeline already has the workaround locally — see euclid_strong_lens_modeling_pipeline/util.py:378:
tracer = fit.tracer_linear_light_profiles_to_light_profilesThis PR lifts that fix into the library so other lens projects using linear profiles get correct values without each one re-discovering the issue.
Fix
Read from fit.tracer_linear_light_profiles_to_light_profiles (which returns the tracer with linear-profile intensities filled in from the inversion's linear_light_profile_intensity_dict):
def total_source_flux_mujy(fit, magzero, xp=np):
...
# tracer_linear_light_profiles_to_light_profiles returns the tracer
# with linear-profile intensities filled in from the inversion.
# For non-linear fits it's a no-op pass-through (returns fit.tracer).
tracer = fit.tracer_linear_light_profiles_to_light_profiles
source_image = tracer.galaxies[-1].image_2d_from(
grid=fit.dataset.grids.lp, xp=xp
)Stress-test:
- Non-linear fits:
autogalaxy/abstract_fit.py:214early-returnsself.model_objwhen no linear profiles are present — pure no-op pass-through, existing tests still pass. - Linear-profile fits:
append_linear_light_profiles_to_model(...)rebuilds the tracer with intensities from the inversion (already cached as a side-effect offigure_of_merit). - JIT path: euclid uses this exact pattern under
LATENT_BATCH_MODE = "jit"in production. magnificationinherits the fix transitively.
total_lens_flux_mujy, total_lensed_source_flux_mujy, and effective_einstein_radius are unchanged — they're already correct.
Test Plan
- Add
test_total_source_flux_mujy_uses_converted_tracer_for_linear_profiles— build a fit fixture wherefit.tracer.galaxies[-1].image_2d_from()returns zeros (unsolved) andfit.tracer_linear_light_profiles_to_light_profiles.galaxies[-1].image_2d_from()returns the expected non-zero image; assert the function reads from the solved tracer. - Update existing
test_total_source_flux_mujy_against_known_imageandtest_magnification_is_lensed_over_intrinsicfixtures to expose the new attribute. -
pytest test_autolens/— full suite (~311 tests) green.
Context
Discovered while reading euclid_strong_lens_modeling_pipeline/util.py:378 during the planning of #17 (Euclid pipeline migration). The euclid migration is paused waiting for this fix to land — once merged, the euclid pipeline can inherit the corrected library and drop its own tracer_linear_light_profiles_to_light_profiles line.
Activity
fix: total_source_flux_mujy wrong value for linear light profiles