Skip to content

VIs that should be re-entrant and aren't #8

Description

@SeasDiver

When creating a Master instance, several VIs are not reentrant and should be. While the VIs are not-reentrant, a parallel application that is trying to instantiate connections with multiple Modbus slaves will block if one is not responding. These VIs are:

  • C:\Program Files (x86)\National Instruments\LabVIEW 2019\vi.lib\Modbus\master\Create Master Instance (TCP).vi
  • C:\Program Files (x86)\National Instruments\LabVIEW 2019\vi.lib\Modbus\subvis\Modbus API\Initialize.vi
  • C:\Program Files (x86)\National Instruments\LabVIEW 2019\vi.lib\Modbus\master\Initialize.vi
  • C:\Program Files (x86)\National Instruments\LabVIEW 2019\vi.lib\Modbus\subvis\Protocol\Interfaces\Network Master\Initialize Master.vi
  • C:\Program Files (x86)\National Instruments\LabVIEW 2019\vi.lib\Modbus\subvis\Protocol\Serial\Serial Master\Initialize Master.vi
  • C:\Program Files (x86)\National Instruments\LabVIEW 2019\vi.lib\Modbus\subvis\Protocol\TCP\TCP Master\Initialize Master.vi
  • C:\Program Files (x86)\National Instruments\LabVIEW 2019\vi.lib\Modbus\slave\Initialize.vi