diff --git a/docs/assets/apollo-mmwave-calibrate-r-pro-1.png b/docs/assets/apollo-mmwave-calibrate-r-pro-1.png index 19b7bc363c..889f1a7049 100644 Binary files a/docs/assets/apollo-mmwave-calibrate-r-pro-1.png and b/docs/assets/apollo-mmwave-calibrate-r-pro-1.png differ diff --git a/docs/assets/apollo-mmwave-ld2450-live-count.png b/docs/assets/apollo-mmwave-ld2450-live-count.png index 69acb9b361..eaf2accdbe 100644 Binary files a/docs/assets/apollo-mmwave-ld2450-live-count.png and b/docs/assets/apollo-mmwave-ld2450-live-count.png differ diff --git a/docs/assets/apollo-mmwave-start-here.png b/docs/assets/apollo-mmwave-start-here.png index 7e290b3ebf..9b0ddf8020 100644 Binary files a/docs/assets/apollo-mmwave-start-here.png and b/docs/assets/apollo-mmwave-start-here.png differ diff --git a/docs/products/general/setup/apollo-mmwave-dashboard-setup.md b/docs/products/general/setup/apollo-mmwave-dashboard-setup.md index 958c04d697..2cc5b5e28f 100644 --- a/docs/products/general/setup/apollo-mmwave-dashboard-setup.md +++ b/docs/products/general/setup/apollo-mmwave-dashboard-setup.md @@ -102,9 +102,6 @@ The cards on each tab are laid out in columns that stack into one on a phone. He Both sensors use the LD2410 radar chip, so their tabs look the same, and the tuning card titles start with **LD2410**. - **Start here** sits at the top. It names your sensor and lists five steps, from **Fix anything the Radar setup card flags.** to walking the room while you watch the Gate Energy chart. Under the steps it says to use **Radar Target** in automations for the whole room, and to raise **Radar Timeout** to 60 s or more if it turns off while someone sits still. Its links open the tuning guide on this wiki and your sensor's own page in Home Assistant. - - ![The Start here card for an MSR-1 named MSR-1 Kitchen, with five numbered steps starting Fix anything the Radar setup card flags., then the line In automations, use Radar Target for the whole room., followed by the Full tuning guide and All settings for this device links](/assets/apollo-mmwave-start-here.png) - - Under it, the **Radar setup** card checks the radar's settings and offers a fix when one is off. On a sensor that's ready to go it reads **Radar settings look good.** - **Auto-calibrate** comes next, with the **Calibrate with empty room** and **Preview only** buttons. If your sensor still has its factory thresholds and has never been calibrated, the card adds **These look like factory thresholds. Calibrating sets them for your room.** - The **LD2410 Gate Energy** chart is dimmed behind **Turn on Radar Engineering Mode to see gate energy values**, with a **Turn on Radar Engineering Mode** button below. That's expected: the radar only reports gate energy while **Radar Engineering Mode**, a diagnostic setting, is on. You don't need to press the button before calibrating; the calibration turns the mode on for its listen and puts it back the way it was afterward. @@ -118,6 +115,9 @@ Both sensors use the LD2410 radar chip, so their tabs look the same, and the tun The R PRO-1 tab starts with the same tuning cards, titled **LD2412** instead of **LD2410**, for the optional LD2412 radar addon, and adds a zone map for its LD2450 radar. Without the addon, the LD2412 cards still appear but have no radar behind them, so skip to the zone map, and **Start here** gives the zone map steps instead. The differences from an MSR-2 tab: - **Start here** says what each radar is for: the LD2412 senses people anywhere in range, even sitting still, and the LD2450 tracks where people are and drives the zone map. For automations that cover the whole room, it names **Combined Presence** (on while either radar sees someone) on firmware newer than 26.3.2.1, which has that sensor, and **LD2412 Presence** on earlier firmware. + + ![The Start here card for an R PRO-1 named R PRO-1 Normal Temperature Test, Apollo mmWave with two radars: the LD2412 senses people anywhere in range, even sitting still, and the LD2450 tracks where people are and drives the zone map. Six numbered steps follow, from Fix anything the LD2412's Radar setup card flags. to the LD2450's zone map steps, then the line In automations, use LD2412 Presence (Radar Target on this tab) for the whole room, or a zone's presence sensor for one part of it., followed by the Full tuning guide and All settings for this device links](/assets/apollo-mmwave-start-here.png) + - **LD2412 Controls** adds **Start Dynamic Background Correction** and **Background Correction Running**. The Auto-calibrate card reminds you to run background correction first, with the room empty, and wait for its status to turn off before you calibrate. - **LD2412 Detection Range** holds **Radar Timeout**, **Max Gate**, and **Min Gate**, plus **Distance Resolution** if you've enabled that entity (it's hidden on a new sensor). - The thresholds cards and the Gate Energy chart cover 14 gates, **G0** to **G13**. diff --git a/docs/products/general/setup/apollo-mmwave-dashboard.md b/docs/products/general/setup/apollo-mmwave-dashboard.md index d903f84b42..e99bf3702e 100644 --- a/docs/products/general/setup/apollo-mmwave-dashboard.md +++ b/docs/products/general/setup/apollo-mmwave-dashboard.md @@ -36,9 +36,9 @@ Every tab starts with a **Start here** card that lists your sensor's first steps - **On MSR-1 and MSR-2 tabs**, a line under the Gate Energy chart says whether the radar reports a target: [Third column](#third-column). - **After an update**, the cards tell you when the page needs a reload: [Load the new cards](apollo-mmwave-dashboard-setup.md#load-the-new-cards). -Here's the **Start here** card on an MSR-1. On an MTR-1, or an R PRO-1 without the LD2412, it lists three zone map steps instead, and on an R PRO-1 with the LD2412 it covers both radars. +Here's the **Start here** card on an R PRO-1 with the LD2412, which covers both radars. On an MSR-1 or MSR-2 it lists five steps for its one radar, and on an MTR-1, or an R PRO-1 without the LD2412, three zone map steps. -![The Start here card for an MSR-1 named MSR-1 Kitchen, with five numbered steps: fix anything the Radar setup card flags, press Calibrate with empty room, set Max Move Gate and Max Still Gate (each gate is about 2.5 ft), set Radar Timeout, and walk the room while you watch the Gate Energy chart, then the line In automations, use Radar Target for the whole room. If it turns off while someone sits still, raise Radar Timeout to 60 s or more. To ignore people past End Zone 3, use Any zone instead., followed by the Full tuning guide and All settings for this device links](/assets/apollo-mmwave-start-here.png) +![The Start here card for an R PRO-1 named R PRO-1 Normal Temperature Test, Apollo mmWave with two radars: the LD2412 senses people anywhere in range, even sitting still, and the LD2450 tracks where people are and drives the zone map. Six numbered steps follow: fix anything the LD2412's Radar setup card flags, press Calibrate with empty room on the Auto-calibrate card and leave the room, set Max Gate and Min Gate on the Detection Range card (each gate is about 2.5 ft), set Radar Timeout on the same card, walk the room while you watch the Gate Energy chart, and for the LD2450 fix anything Radar setup flags above the zone map, set Cone rotation under Map settings, then press Add zone, draw the zone, and walk into it. Then the line In automations, use LD2412 Presence (Radar Target on this tab) for the whole room, or a zone's presence sensor for one part of it., followed by the Full tuning guide and All settings for this device links](/assets/apollo-mmwave-start-here.png) !!! note "Before you start" @@ -239,7 +239,7 @@ Every R PRO-1 has an LD2450 radar, and the optional LD2412 addon adds a second o - There is no Zone Config card, and the Distances chart shows the gates and the Max Gate and Min Gate bars without live distance bars. - Before it writes, the calibration asks the radar for its current thresholds (**Reading the radar's current thresholds...**), so what it saves for Undo matches the radar. -![The Auto-calibrate card on an R PRO-1, titled LD2412 · R PRO-1 Server Rack, with a fourth checklist item asking you to run Start Dynamic Background Correction first, and under the checklist the reminder to raise Radar Timeout to 60 s or more if Radar Target turns off while someone sits still](/assets/apollo-mmwave-calibrate-r-pro-1.png) +![The Auto-calibrate card on an R PRO-1, titled LD2412 · R PRO-1 Normal Temperature Test, with a fourth checklist item asking you to run Start Dynamic Background Correction first, the reminder to raise Radar Timeout to 60 s or more if Radar Target turns off while someone sits still, the Calibrate with empty room and Preview only buttons, then Last calibrated Oct 21, 08:02 AM, 7 of 28 thresholds changed., the Undo (restore your previous values) button with Saved Oct 21, 08:02 AM. under it, and Show last result](/assets/apollo-mmwave-calibrate-r-pro-1.png) The LD2412 also has its own background learning, **Start Dynamic Background Correction** on the **LD2412 Controls** card. It runs on the radar chip and stores its result inside the radar. **Background Correction Running** shows whether it is still working. Use both, in this order: @@ -510,7 +510,7 @@ Reload the page after you add a zone, and the **Zone presence** card next to the Under it, **LD2450 Live** shows what the radar reports right now, with the radar's **Target Count** under its rows as a whole number. If the map shows no dot with you in the room, look here first: **LD2450 Presence** off means the radar itself reports nobody. It covers the radar's whole view, not one zone, and **Occupancy History** names its line **LD2450 Presence** too. -![The LD2450 Live card on an R PRO-1 with nobody in the room: LD2450 Presence, Moving Target, and Still Target read Clear, and Target 1 to 3 Distance read Unknown with their Direction rows reading NA. A second card under it reads Target Count: 0, with the 0 in bold](/assets/apollo-mmwave-ld2450-live-count.png) +![The LD2450 Live card on an R PRO-1 with one person in the room: LD2450 Presence, Moving Target, and Still Target read Detected, Target 1 Distance reads 15.6 in and Target 1 Direction reads Approaching, and Target 2 and 3 Distance read Unknown with their Direction rows reading NA. A second card under it reads Target Count: 1, with the 1 in bold](/assets/apollo-mmwave-ld2450-live-count.png) For an automation that covers the whole room rather than one zone, **Start here** names the sensor to use. On an MTR-1 it's **LD2450 Presence**. On an R PRO-1 whose firmware has **Combined Presence** (firmware newer than 26.3.2.1), it's **Combined Presence**, which is on while either radar sees someone. On earlier R PRO-1 firmware it's **LD2412 Presence**, or **LD2450 Presence** on an R PRO-1 without the LD2412.